{"id":168,"date":"2020-02-16T19:58:05","date_gmt":"2020-02-16T17:58:05","guid":{"rendered":"https:\/\/tekmart.co.za\/t-blog\/?p=168"},"modified":"2020-02-16T20:11:26","modified_gmt":"2020-02-16T18:11:26","slug":"how-to-replace-a-failed-dell-equallogic-controller","status":"publish","type":"post","link":"https:\/\/tekmart.co.za\/t-blog\/how-to-replace-a-failed-dell-equallogic-controller\/","title":{"rendered":"How to replace a Failed Dell EqualLogic Controller"},"content":{"rendered":"<span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time-approximately:<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"168\" class=\"elementor elementor-168\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7a9a2edf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7a9a2edf\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-34b5af53\" data-id=\"34b5af53\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-845a2f4 elementor-widget elementor-widget-image\" data-id=\"845a2f4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"520\" src=\"https:\/\/tekmart.co.za\/t-blog\/wp-content\/uploads\/2020\/02\/failed-dell-equallogic-controller.png\" class=\"attachment-large size-large wp-image-175\" alt=\"EqualLogic Controller\" srcset=\"https:\/\/tekmart.co.za\/t-blog\/wp-content\/uploads\/2020\/02\/failed-dell-equallogic-controller.png 800w, https:\/\/tekmart.co.za\/t-blog\/wp-content\/uploads\/2020\/02\/failed-dell-equallogic-controller-300x195.png 300w, https:\/\/tekmart.co.za\/t-blog\/wp-content\/uploads\/2020\/02\/failed-dell-equallogic-controller-768x499.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74f0eecb elementor-widget elementor-widget-text-editor\" data-id=\"74f0eecb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<h2 class=\"wp-block-heading\"><b>What to do when an <a href=\"https:\/\/www.tekmart.co.za\/70-0101-dell-equallogic-type-3-ps3000-controller-blue-71350-13\">EqualLogic Controller<\/a> Fails<\/b><\/h2>\n<p><\/p>\n<p><\/p>\n<p><em>The procedures may vary&nbsp;when a control module (member) is removed or fails depending on the number and type of control modules, the network cabling configuration, and the cache mode settings. Please see the Hardware Maintenance manual for your array model for detailed information about array-specific control module and network failover behavior. Use this guide at your own risk. Tekmart Africa <a href=\"mailto:support@tekmart.co.za\">Support<\/a> is not responsible for faults, failures, data loss, etc. as a result of following this guide.<\/em><\/p>\n<p><\/p>\n<p><\/p>\n<p>In a dual control module array, if the secondary control module is removed or fails, the remaining control module may enter write-through mode depending on the cache mode policies.<\/p>\n<p><\/p>\n<p><\/p>\n<p>In a dual control module array, if the active control module fails, the secondary control module automatically takes over and become active. If there is a network connection to the active control module, the control module failover will be transparent to applications; however, iSCSI initiators must reconnect to the group IP address.<\/p>\n<p><\/p>\n<p><\/p>\n<p>If the only functioning control module fails, the controller will be inaccessible from the network and data loss is possible.<\/p>\n<p><\/p>\n<p><\/p>\n<p>If a control module fails, replace it as soon as possible with the same control module type.<\/p>\n<p><\/p>\n<p><\/p>\n<p><strong>Caution:<\/strong>&nbsp;Do not mix control module types in an array.<\/p>\n<p><\/p>\n<p><\/p>\n<p>For information about replacing a control module, see the Hardware Maintenance manual for your array model or contact your array support provider.<\/p>\n<p><\/p>\n<p><\/p>\n<p><strong>Do not remove a failed control module until you have a replacement.<\/strong><\/p>\n<p><\/p>\n<p><\/p>\n<p><strong>NOTE:<\/strong>&nbsp;For proper cooling, do not leave a control module slot empty. If an array will operate for a long time with only one control module, you must install a blank control module in the empty slot. You can order a blank control module from your PS Series array service provider. If you remove the active control module, there will be a short interruption as failover to the secondary control module occurs.<\/p>\n<p><\/p>\n<p><\/p>\n<h3 class=\"wp-block-heading\"><b>How to Tell if Dell EqualLogic Controller has Failed<\/b><\/h3>\n<p><\/p>\n<p><\/p>\n<p>You can identify a failed control module by:<\/p>\n<p><\/p>\n<p><\/p>\n<ol class=\"wp-block-list\">\n<li>LEDs \u2013 failed control module may appear as ACT LED no color, ERR LED is red, PWR LED is Off<\/li>\n<li>Messages \u2013 A message on the LCD panel (located behind the bezel), on the console, in the event log, or in the Group Manager GUI Alarms panel describes a control module failure<\/li>\n<li>Group Manager GUI and CLI Output \u2013 The Member Controllers window or the member select \u201cshow controllers command output\u201d shows the control module status \u201cnot installed\u201d.<\/li>\n<\/ol>\n<p><\/p>\n<p><\/p>\n<p>If a controller\/control module has failed you must replace it.<\/p>\n<p><\/p>\n<p><\/p>\n<h2 class=\"wp-block-heading\"><b>How to Replace a Dell EqualLogic Controller<\/b><\/h2>\n<p><\/p>\n<p><\/p>\n<ol class=\"wp-block-list\">\n<li>Follow safety and\/or ESD protocols.<\/li>\n<li>Make sure the faulty controller is the SECONDARY controller. If not, you must fail over the array (see below).<\/li>\n<li>With faulted controller in the secondary position, disconnect all of the cables (noting their location).<\/li>\n<li>Remove the controller by operating latches. The array should continue to function on the active controller.<\/li>\n<li>Remove the flash card from the faulty controller. (May be a compact flash card or micro SD card)<\/li>\n<li>Insert the flash card into the replacement controller.<\/li>\n<li>Correctly orient and insert the replacement controller and ensure it is properly seated.<\/li>\n<li>Reconnect cables to the replacement controller.<\/li>\n<li>Check LEDs and GUI to ensure that the replacement controller has come online.<\/li>\n<\/ol>\n<p><\/p>\n<p><\/p>\n<p><strong>NOTE:<\/strong>&nbsp;After replacing the controller if the array reports a critical hardware error with no hardware issues showing, remove the new controller following the steps above, and wait 60 seconds to reseat it. This should clear the error.<\/p>\n<p><\/p>\n<p><\/p>\n<p>If two control modules are installed but only one appears in the GUI or CLI, the control module may not be properly installed. Re-install the control module. If both control modules still do not appear in the GUI or CLI, they may not be running the same firmware. Contact your array support provider<\/p>\n<p><\/p>\n<p><\/p>\n<h2 class=\"wp-block-heading\"><b>How to Fail Over Dell EqualLogic Controller Array<\/b><\/h2>\n<p><\/p>\n<p><\/p>\n<p>To fail over one control module to another, you must \u201crestart\u201d the Active control module, which will force the Secondary controller to take over and make the \u201ccurrently active\u201d controller the original Secondary controller.<\/p>\n<p><\/p>\n<p><\/p>\n<ol class=\"wp-block-list\">\n<li>In the GUI (Group Manager) click on \u201cMembers\u201d and select the array in question.<\/li>\n<li>On the tabs on the right side of the GUI, click on \u201cMaintenance\u201d.<\/li>\n<li>Locate and click on the \u201cRestart\u201d button.<\/li>\n<li>You will be prompted for the grpadmin password.<\/li>\n<\/ol>\n<p><\/p>\n<p><\/p>\n<p><strong>NOTE:<\/strong>&nbsp;You will see alerts such as \u201cUnable to communicate to the other control module, active fail over cannot occur\u201d. This should resolve after a minute or two once the restart has completed.<\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p><span class=\"span-reading-time rt-reading-time\" style=\"display: block;\"><span class=\"rt-label rt-prefix\">Reading Time-approximately:<\/span> <span class=\"rt-time\"> 3<\/span> <span class=\"rt-label rt-postfix\">minutes<\/span><\/span>What to do when an EqualLogic Controller Fails The procedures may vary&nbsp;when a control module (member) is removed or fails depending on the number and type of control modules, the network cabling configuration, and the cache mode settings. Please see the Hardware Maintenance manual for your array model for detailed information about array-specific control module and network failover behavior. Use<\/p>\n<p><a class=\"more-link\" href=\"https:\/\/tekmart.co.za\/t-blog\/how-to-replace-a-failed-dell-equallogic-controller\/\">Read More<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,16,12],"tags":[],"class_list":["post-168","post","type-post","status-publish","format-standard","hentry","category-datacenter-news","category-how-tos-and-other-useful-tips-and-tricks","category-tekmart-enterprise-hardware-tips"],"_links":{"self":[{"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/posts\/168","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/comments?post=168"}],"version-history":[{"count":11,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/posts\/168\/revisions"}],"predecessor-version":[{"id":181,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/posts\/168\/revisions\/181"}],"wp:attachment":[{"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/media?parent=168"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/categories?post=168"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/tekmart.co.za\/t-blog\/wp-json\/wp\/v2\/tags?post=168"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}