Identifying which generation your Dell PowerEdge server belongs to in your data center
T-Blog Editor/ April 4, 2020/ Data Center Hardware, How-Tos and Other Useful Tips and Tricks, Partner Resources, Tekmart Enterprise Hardware Tips
Reading Time-approximately: 4 minutes
You might have come across Dell PowerEdge servers being referred to by their generation to cover a range of models.
For example 11G, 12G, 13G, or 14G (14th generation). Here we will explain how to identify which generation of a server you have.
Starting with the 10th Generation of PowerEdge servers, the naming for the server models generally consist of a letter(s) followed by three or four numbers (ex: PowerEdge R710 or PowerEdge R6415 or MX740c).
The letter indicates the type (form factor) of the server:
- C = Cloud – Modular server nodes for hyper-scale environments
- F = Flexible – Hybrid rack-based sleds for rack-based FX2/FX2s enclosure
- M or MX* = Modular – Blade servers and other items for the modulal enclosure MX7000, M1000e and/or VRTX
- R = Rack-mountable servers
- T = Tower Servers
For three number naming convention:
– The first number after the letter indicates the class of the system. With 1-3 being 1 CPU systems, 4 – 7 are 2 CPU systems, 8 can be 2 or 4 CPU’s and 9 is 4 CPU’s.
– The second number indicates the generation, with 0 for 10th generation, 1 for 11th generation and so on.
– The third number indicates the make of the CPU, 0 for Intel and 5 for AMD.
So, for example, the R710 model is a Rack 2 CPU system from the 11th generation of servers with Intel Processors.
For four number naming convention:
– The first number after the letter indicates the class of the system. With 1-5 defaulting to iDRAC Basic and 6 – 9 defaulting to iDRAC Express.
– The second number indicates the generation, with 0 for 10th generation, 1 for 11th generation and so on.
– The third number indicates the number of CPUs, 1 for 1 CPU and 2 for 2 CPU’s.
– The fourth number indicates the make of the CPU, 0 for Intel and 5 for AMD.
So, for example, the R6415 model is a Rack 1 CPU socket system from the 14th generation of servers with AMD Processors.
* For MX7000 modular enclosure: compute sleds, storage sled and IO modules are identified with an additional letter appended to the end of the model name.
- MX740c or MX840c has an appended c for Compute
- MX5016s has an appended s for Storage
- MX9116n has an appended n for IO Module
Before the 10th generation of PowerEdge servers, the Naming convention used 4 digits (ex: PowerEdge 2950) where the digits represent:
- First digit – Class of server
- Second digit – Generation of server (up to 9th generation)
- Third digit – Server type (5 for rack server, 0 for tower server)
- Fourth digit – Indicated whether blade or independent box (5 for blade, 0 for normal independent box)
So, for example, the 2950 model is a 2U system from the 9th generation of servers in Rack format in an independent box.
| Generation | 14G | 13G | 12G | 11G | 10G |
|---|---|---|---|---|---|
| C Series | C4140 C6420 | C4130 C6320 | C6220 C6220 II C8000 C8220 C8220X C8220XD | C410x C1100 C2100 C5000 C5125 C5220 C6100 C6105 C6145 | |
| Modular Models | FC640 M640 M640 (for PE VRTX) MX740c MX840c MX5016s | FC430 FC630 FC830 FD332 FM120 M630 M630 (for PE VRTX) M830 M830 (for PE VRTX) | M420 M520 M520 (for PE VRTX) M620 M620 (for PE VRTX) M820 M820 (for PE VRTX) | M610 M610x M710 M710HD M910 M915 | M600 M605 M805 M905 |
| Rack Models | R240 R340 R440 R540 R640 R6415 R740 R740xd R740xd2 R7415 R7425 R840 R940 R940xa | R230 R330 R430 R530 R630 R730 R730xd R830 R930 | R220 R320 R420 R420xr R520 R620 R720 R720xd R820 R920 | R210 R210 II R310 R410 R415 R510 R515 R610 R710 R715 R810 R815 R910 | R200 R300 R805 R900 R905 |
| Tower Models | T140 T340 T440 T640 | T30 T130 T330 T430 T630 | T20 T320 T420 T620 | T110 T110 II T310 T410 T610 T710 | T100 T105 T300 T605 |
Exceptions:
PowerEdge MX7000
The PowerEdge MX7000 was introduced during the 14th Generation range. The MX7000 enclosure has eight front-accessible slots for 2-socket single-width or 4-socket double-width compute sleds and single-width storage sled combinations. The supported server module sleds are designated as MXxxxc. The supported storage module sleds are designated as MXxxxxs
For MX7000 modular: compute sleds, storage sled and IO modules are identified with an additional letter appended to the end of the model name.
- MX740c or MX840c has an appended c for Compute sled
- MX5016s has an appended s for Storage sled
- MX9116n has an appended n for IO Module
- MXG610s has an appended s for IO Module
PowerEdge M1000E
The PowerEdge M1000e was introduced during the 10th Generation range. The M1000e enclosure includes up to 16 half-height server modules, eight full-height server modules, eight sleeves with quarter-height server modules, or a mix of the three server module types. The supported server module types are designated as Mxxx.
Follow this procedure to install server modules that are not configured for the M1000e enclosure:Note: If you install server modules that are not configured for the M1000e enclosure, an error message is displayed.
To configure a Mxxx (for PE VRTX) server module for the M1000e enclosure from the VRTX enclosure:
- Open the server module.
- Remove any PCIe Mezzanine cards installed in Fabric B and Fabric C slots of the server module.
- Install Mezzanine card slot B that supports Fabric B. This card must match the fabric type of I/O modules B1 and B2 of the M1000e.
- Install Mezzanine card slot C that supports Fabric C. This card must match the fabric type of I/O modules C1 and C2 of the M1000e.
PowerEdge VRTX
The PowerEdge VRTX was introduced during the 12th Generation range. The VRTX enclosure includes up to four half-height server modules, two full-height server modules, or a mix of the server module types. The supported server module types are designated as Mxxx (for PE VRTX).
Follow this procedure to install server modules that are not configured for the VRTX enclosure.Note: If you install server modules that are not configured for the VRTX enclosure, an error message is displayed.
To configure a Mxxx server module for the VRTX enclosure from the M1000e enclosure:
- Open the server module.
- Remove any mezzanine cards installed in Fabric B and Fabric C slots of the server module.
- Install PCIe Mezzanine cards in the vacant Fabric B and Fabric C slots.
PowerEdge FX2 / FX2s
The PowerEdge FX2/FX2s was introduced during the 13th Generation range. The FX2 enclosure supports up to four half-width compute sleds, up to eight quarter-width compute sleds, up to two full-width compute sleds, or a mix of compute sled types. The PowerEdge FX2s enclosure also supports half-width storage sleds mapped to the compute sleds. The supported compute sleds are designated as FCxxx and FMxxx. The supported storage sleds are designated as FDxxx.