Dell Rack 200-240V B0010 Series of Power Distribution Units Part #: 0TRVV3 / TRVV3 / CN-0TRVV3 / 450-15690
- Brand: Dell
- Part #: 0TRVV3
- Alt. Part #: TRVV3 / CN-0TRVV3 / 450-15690
- Dell Model: B0010
- Specs:-
- :: Voltage: Typically rated for 200-240 VAC (for data center environments).
- :: Form Factor: Often a Vertical or 1U Rackmount PDU (depending on the exact sub-model).
- :: Input Current: Commonly seen in 32A or 60A configurations.
- :: Phase: Can be Single-Phase or 3-Phase depending on the specific model variation.
- Outlets: Features a large number of outlets for connecting equipment, usually a combination of:
- :: IEC 320-C13 sockets (Standard server power cables)
- :: IEC 320-C19 sockets (High-power device cables, common on high-wattage power supplies)
- Compatibility:
- :: Dell Poweredge Rack Systems
- :: Condition: New
- :: MPN: 0TRVV3
- Warranty: 1 (one) year Tekmart Africa warranty
-
INT030324DSC2025
**Eligible for immediate collection / shipping upon order confirmation*
The SKU: 0TRVV3 (or TRVV3) is a Dell part number and refers to a Power Distribution Unit (PDU).
This is a piece of equipment used in a server rack to distribute electrical power to servers, storage devices, and networking gear. Its primary uses are to provide reliable, high-density power distribution within a standard server rack enclosure.
These PDUs are essential infrastructure for a Dell server rack, providing the necessary power connections for multiple Dell PowerEdge servers and other hardware.
Primary Uses and Functions
1. High-Density Power Distribution:
::The PDU takes a single, high-capacity power input (e.g., a 32A or 60A circuit) and splits it into many individual, standard outlets (typically 21 x IEC C13 and 6 x IEC C19 sockets).
::This is essential for powering multiple servers, storage arrays, and networking switches densely packed into a single rack.
2. Rack Space Optimization:
::The 0TRVV3 PDU often comes in a Vertical (0U) form factor, meaning it mounts along the side of the rack rails. This design maximizes the 1U/2U space for servers and other IT equipment.
3. Circuit Protection and Load Balancing:
::It helps distribute the power load evenly across the input phases (often a 3-Phase input for the 60A model) to prevent overloading any single circuit breaker, which is critical for maintaining server uptime.
::While the B0010 is often a Basic PDU, its core function provides a managed and organized point of power delivery compared to simply using power strips.
4. Standardized Connectivity:
::The PDU uses worldwide standard IEC C13 and C19 outlets, which are the standard power connections for nearly all enterprise-grade servers (like Dell PowerEdge) and IT equipment.